Sign In | Join Free | My infospaceinc.com
China ASLi (China) Test Equipment Co., Ltd logo
ASLi (China) Test Equipment Co., Ltd
Customer satisfaction is our ultimate goal.
Verified Supplier

5 Years

Home > Vibration Table Test Equipment >

Electrodynamic Vibration Shaker Meet DO-160G RTCA-160G ISTA 3A Stardard

ASLi (China) Test Equipment Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Electrodynamic Vibration Shaker Meet DO-160G RTCA-160G ISTA 3A Stardard

Brand Name : ASLI

Model Number : ES-50

Certification : CE

Place of Origin : China

MOQ : 1

Price : negotiable

Payment Terms : T/T

Supply Ability : 30 set per month

Delivery Time : 30-35 work days after deposit

Packaging Details : export standard plywood case

sine force : 50000N

speed : 2.0m/s

displacement : 100mm

frequency : 1~3500HZ

loading : 750kg

Acceleration : 100g

armature : 450mm

test standard : DO-160G , RTCA-160G, ISTA 3A

Table Size : 800x800mm

application : LED, auto parts

Contact Now

High Frequency Vibration Test Stand ES-30.pdf

Electrodynamic Vibration Shaker Meet DO-160G , RTCA-160G, ISTA 3A Stardard

Random Sine and Shock Function Electrodynamic Vibration Shaker System is widely used in defense, aviation, aerospace, communications, electronics, automobiles, home appliances, and other industries. This type of equipment is used for discovering the early faults, simulating the actual working condition and the structure strength test, the product application is wide, the application width is obvious, the test effect is remarkable and reliable. Sine wave, FM, sweep, programmable, frequency multiplier, logarithm, maximum acceleration, amplitude modulation, time control, full function computer control, simple fixed acceleration/fixed amplitude. Equipment through continuous failure to run 3 months of testing, stable performance, reliable quality.

Vibration Shaker Specifications
Peak Sine (Pk) 5000Kg.f peak (50KN)
Random (RMS) 5000Kg.f r.ms (50KN)
Shock (Pk) 10000Kg.f peak (100KN) @6ms
Usable Frequency 1~2500Hz
Maximum Displacement (p-p) 100mm (4 inch) , 76mm (3inch) continuous
Max. velocity 2m/s
Max. acceleration Sine:100g (980 m/s2), Random 62g(600 m/s2)
Vertical Load Support 500 kg

Body Suspension Natural

Frequency (Thrust Axis)

Less than 2.5 Hz
Armature Diameter Ф440 mm
Armature Weight 59kg

Fundamental Resonance

Frequency (Bare table)

2,400 Hz (nom.) +/- 5%

Load Attachment

Points (Standard)

16 stainless steel M10 Inserts
Stray Flux Density <10 gauss
Shaker dimensions 1670mmL×1150mmD×1300mmH
Weight of Shaker About 4600Kg
Compressed Air Requirement 0.6 Mpa

Electrodynamic Vibration Shaker Meet DO-160G RTCA-160G ISTA 3A Stardard

More Specification

Name Automobile Battery EN50604 IEC62133 UN38.3 Vibration Test Bench for Lab testing
Model Rated Sine Force (N) Rated Random Force (N) Frequency Range (Hz) Rated Acceleration (m/s2) Rated Speed(m/s) Rated displacement (p-p)mm Max. Loading (Kg) moving coil (Kg) Dimension of Moving coil (mm)
ES-6 6000 6000 3-3500 1000 1.6 25 180 6.5 Φ230
ES-6a 6000 6000 3-3500 1000 1.6 51 250 12 Φ230
ES-10 10000 10000 3-3000 1000 1.8 51 270 14 Φ240
ES-20 20000 20000 3-3000 1000 1.8 51 300 30 Φ320
ES-30 30000 30000 3-2800 1000 1.8 5l 450 40 Φ450
ES-40 40000 40000 3-2800 1000 1.8 51 500 50 Φ450
ES-50 50000 50000 3-2700 1000 1.8 51 750 50 Φ450
ES-60 60000 60000 3-2700 1000 1.8 51 750 60 Φ450
ES-100 100000 100000 3-2500 1000 1.8 51 1000 90 Φ450

Electrodynamic Vibration Shaker Meet DO-160G RTCA-160G ISTA 3A Stardard

Electrodynamic Vibration Shaker Meet DO-160G RTCA-160G ISTA 3A Stardard

Electrodynamic Vibration Shaker Meet DO-160G RTCA-160G ISTA 3A Stardard

Electrodynamic Vibration Shaker Meet DO-160G RTCA-160G ISTA 3A Stardard

Electrodynamic Vibration Shaker Meet DO-160G RTCA-160G ISTA 3A StardardElectrodynamic Vibration Shaker Meet DO-160G RTCA-160G ISTA 3A Stardard

Electrodynamic Vibration Shaker Meet DO-160G RTCA-160G ISTA 3A Stardard

1. Well-designed dynamic circle skeleton, with a higher stage axial resonance frequency.

2. Two-magnetic circuit, magnetic flux leakage low, compact structure and rational.


3. Rocker Rod roller bearings straight and import-oriented composite body stiffness orientation, eccentric load capacity.

4. Trunnion isolation foundation dedicated to hormone use, the installation of mobile convenience.

5. Advanced technology move around the system to ensure that the dynamic circle of high reliability.

6. New duct design and enhance the cooling effect.

7. Static stiffness, dynamic stiffness of the bearing small balloon, raising the vibration table bearing capacity, improve low-frequency performance.
The Electrodynamic Vibration Shaker Meet DO-160G , RTCA-160G, ISTA 3A Stardard also can be combined with temperature humidity chamber to use

Product Tags:

50000N Electrodynamic Vibration Shaker

      

LED Electrodynamic Vibration Shaker

      

RTCA-160G Vibration Table Test Equipment

      
Quality Electrodynamic Vibration Shaker Meet DO-160G RTCA-160G ISTA 3A Stardard for sale

Electrodynamic Vibration Shaker Meet DO-160G RTCA-160G ISTA 3A Stardard Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: ASLi (China) Test Equipment Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)